Finned Tube Heat Exchanger
                
                
                 
                  Technical Details
                  
                    
Heat Exchanger
a] Inner tube - j 12.7 mm I. D. copper tube, 1 mtr. long, .
 b] Outer tube - j 25 mm I. D G.I. pipe. 1 mtr. long, with air piping
                    Electric heaters - 3 Kw capacity, 1 Nos.to supply hot water
                    Blower - Centrifugal blower to force the air, driven by single phase Electric motor
                    Orifice with water manometer to measure the air flow. Orifice dia - 14 mm.
                    Measuring cylinder - 1 lit. to measure water flow.
                    Valves for flow control and change of air flow direction.
                    Digital temperature indicator to measure the temperatures of hot and cold Water
                  
                 
                
                  
Range Of Experiment
                  Determination of overall heat transfer co efficient for a tube –in–tube type heat transfer. To calculate
                    i) Rate of heat transfer
                    ii) Theoretical over all heat transferco efficient
                  
                  To compare the performance of Parallel flow & Counter flow heat exchanger.